MODULE: fitcoords
SYSTEM: V2.10-V2.11.1
SYSTEM: V2.10-V2.11.1
NUMBER: 430 MODULE: fitcoords SYSTEM: V2.10-V2.11.1 DATE: Wed Jul 21 16:52:49 MST 1999 FROM: valdes BUG: When the fitting orders are higher than the data allow the task should report 'No degrees of freedom' and abort but instead the error is not caught and the task proceeds causing various errors including segmentation violations, crashing the cl, and 'task cursor not found'. One way this can be triggered inadvertently is if one forgets to trace the feature(s) with REIDENTIFY. The solutions are to remember to trace the features and to use orders that are lower than the number of points traced. STATUS: In the next release the task will report 'No degrees of freedom' and abort rather than mysteriously crashing. It will also report 'Only one line or column measured' and abort if the feature(s) have not been traced to other lines or columns.