Welcome to iraf.net Wednesday, May 08 2024 @ 04:27 AM GMT
Buglog #249
- Tuesday, June 21 1994 @ 08:35 PM GMT
- Contributed by: admin
- Views: 1,130
MODULE: sarith
SYSTEM: V2.10
SYSTEM: V2.10
NUMBER: 249 MODULE: sarith SYSTEM: V2.10 DATE: Tue Jun 21 14:35:17 MST 1994 FROM: valdes BUG: When doing a binary operation with a constant second operand and 'onedspec' output format the constant used is incorrect due to a bug in which the number is used as a real number but is actually a double precision number. The incorrect value can be seen in the verbose output. For example: cl> sarith specin - 48.5 specout format=onedspec verbose+ specin[1] - 3.128906 --> specout.0001 The workaround is to use multispec output format for the operation. A later SCOPY can then be used to convert formats if desired. STATUS: Fixed in V2.11. NUMBER: 289 MODULE: apscatter SYSTEM: V2.9-V2.10.3 DATE: Wed May 3 16:50:54 MST 1995 FROM: valdes BUG: When not smoothing the scattered light surface along the dispersion, smooth=no, and there are multiple apertures the task may abort with the error 'Range descriptor undefined'. This occurs when the number of scattered light points being fit across the dispersion changes as the spacing between apertures changes. This is probably a rare event. The only workaround is to add the smoothing along the dispersion. STATUS: Fixed in after V2.10.3.