MODULE: doslit (specred, kpnocoude, kpnoslit)
SYSTEM: V2.10.3BETA
SYSTEM: V2.10.3BETA
NUMBER: 274 MODULE: doslit (specred, kpnocoude, kpnoslit) SYSTEM: V2.10.3BETA DATE: Tue Jan 24 13:56:11 MST 1995 FROM: valdes BUG: If the first object spectrum has more than one object on the slit and apertures are defined for them then after doing the dispersion solution on the reference arc the following error occurs: ERROR ... - Missing reference for aperture 2 This is a bug, introduced in V2.10.3BETA, since the intent of the task is to allow multiple apertures per long slit spectrum. It is caused by using the apertures from the first object as the apertures for the arc reference. The workarounds are 1) make the first object image be one that has only one aperture (other objects can have multiple apertures) or 2) when in IDENTIFY doing the arc reference dispersion solutions do 'k' after finishing the dispersion solution to step to the other (unnecessary) apertures and do a solution with 'a' 'c' and 'f' (all center and fit). STATUS: Fixed in later versions.