Welcome to iraf.net Thursday, May 09 2024 @ 12:04 AM GMT
Buglog #249
- Tuesday, June 21 1994 @ 08:35 PM GMT
- Contributed by: admin
- Views: 1,167
MODULE: sarith
SYSTEM: V2.10
SYSTEM: V2.10
NUMBER: 249 MODULE: sarith SYSTEM: V2.10 DATE: Tue Jun 21 14:35:17 MST 1994 FROM: valdes BUG: When doing a binary operation with a constant second operand and 'onedspec' output format the constant used is incorrect due to a bug in which the number is used as a real number but is actually a double precision number. The incorrect value can be seen in the verbose output. For example: cl> sarith specin - 48.5 specout format=onedspec verbose+ specin[1] - 3.128906 --> specout.0001 The workaround is to use multispec output format for the operation. A later SCOPY can then be used to convert formats if desired. STATUS: Fixed in V2.11.