MODULE: daophot
SYSTEM: V2.10
NUMBER:	204
MODULE:	daophot
SYSTEM:	V2.10
DATE:	Tue Feb 16 09:08:48 MST 1993
FROM:	davis

BUG:	The parameters psfrad, fitrad, and matchread were being written
	to the daopars parameter set in pixel units instead of scale units
	if the daophot task update parameter was on.

STATUS:	Fixed for the next release of iraf. There is no workaround except
	to turn off the update parameter or always check the input
	parameters using the verify parameter.

Comments (0)