Welcome to iraf.net Thursday, April 25 2024 @ 05:26 PM GMT
Buglog #547
- Monday, April 25 2005 @ 04:59 PM GMT
- Contributed by: admin
- Views: 1,623
MODULE: argus, ctioslit, hydra, iids, irs, kpnocoude, kpnoslit
SYSTEM: V2.12a-V2.12b
SYSTEM: V2.12a-V2.12b
NUMBER: 547 (see also 544) MODULE: argus, ctioslit, hydra, iids, irs, kpnocoude, kpnoslit SYSTEM: V2.12a-V2.12b DATE: Mon Apr 25 10:59:24 MST 2005 FROM: valdes BUG: Changes to SCOMBINE in V2.12.2a made it a separate executable. The package definitions for the packages listed above (see also number 544 concerning the ECHELLE package) failed to be updated so when trying to run SCOMBINE (or a task that calls SCOMBINE such as DOHYDRA) the following error message is produced. ERROR: task `scombine' has no param file The solution is editing the$ .cl file, where is one of the modules listed above, so that it reads as shown below. A simpler workaround is to load the onedspec package and run scombine from that package. STATUS: Fixed for the next release. Modifications to $ .cl: ... task ..., [scombine,] <-- Delete line ..., ... = onedspec$x_onedspec.e task scombine = 'onedspec$scombine/x_scombine.e' <-- Add line ... Note that scombine has to be removed from the first block of task definitions and added as a separate task statement as shown.
The following comments are owned by whomever posted them. This site is not responsible for what they say.