MODULE: identify
SYSTEM: V2.10-2.11.1
SYSTEM: V2.10-2.11.1
NUMBER: 420 MODULE: identify SYSTEM: V2.10-2.11.1 DATE: Mon Mar 8 13:27:24 MST 1999 FROM: valdes BUG: If one uses the 'l' key to identify lines from a line list in a spectrum that is wavelength calibrated and has physical coordinates different from logical coordinates, wrong results or a system error (such as a segmentation error) will occur. This is due to conversion of the line list coordinate to a physical pixel coordinate and attempting to use this to find a peak in the spectrum where the routine expects a logical coordinate. This situation is quite rare and does not occur in normal data reductions. Logical and physical pixel coordinates become different if a section of a spectrum is extracted; such as with IMCOPY or SCOPY. The workaround is to reset the physical coordinates to be the same as the logical coordinates with the command cl> wcsresetwcs=physical STATUS: Fixed for the next release.