Welcome to iraf.net Thursday, March 28 2024 @ 09:57 AM GMT
Buglog #391
- Thursday, February 12 1998 @ 05:29 PM GMT
- Contributed by: admin
- Views: 1,139
MODULE: splot, fitprofs
SYSTEM: V2.10-V2.11.1
SYSTEM: V2.10-V2.11.1
NUMBER: 391 MODULE: splot, fitprofs SYSTEM: V2.10-V2.11.1 DATE: Thu Feb 12 10:29:40 MST 1998 FROM: valdes BUG: A mixture of profile types in deblending or profile fitting may result in a floating point error. The only mixture that will work is if the first profile is 'voigt'. So what works is all profiles of the same type or voigt first plus anything else. This means the only combination that will not work and for which there is no workaround is a combination of 'lorentz' and 'gaussian'. STATUS: Fixed in the next release. NUMBER: 392 MODULE: splot, fitprofs SYSTEM: V2.10-V2.11.1 DATE: Thu Feb 12 11:01:44 MST 1998 FROM: valdes BUG: This is an amendment to buglog 391. The error reported in buglog 391 will only occur when computing errors with the bootstrap method. The fitting without the error computation can use any combination of profiles. STATUS: The error is fixed in the next release.