Welcome to iraf.net Friday, April 19 2024 @ 09:30 AM GMT
Buglog #363
- Tuesday, March 04 1997 @ 04:17 PM GMT
- Contributed by: admin
- Views: 1,023
MODULE: dispcor
SYSTEM: V2.10.2-V2.10.4p2
SYSTEM: V2.10.2-V2.10.4p2
NUMBER: 363 MODULE: dispcor SYSTEM: V2.10.2-V2.10.4p2 DATE: Tue Mar 4 09:17:37 MST 1997 FROM: valdes BUG: Input spectra which are in two dimensional images, have an 'equispec' coordinate system, and log sampled (DC-FLAG=1), are not properly resampled by DISPCOR. One dimensional images and 'multispec' coordinate systems do not have this problem. The workaround is to convert all the spectra to one dimensional images with SCOPY and format='onedspec'. STATUS: Fixed for the next release.
The following comments are owned by whomever posted them. This site is not responsible for what they say.