Welcome to iraf.net Friday, April 19 2024 @ 09:30 AM GMT

Buglog #363

  • Tuesday, March 04 1997 @ 04:17 PM GMT
  • Contributed by:
  • Views: 1,023
MODULE: dispcor
SYSTEM: V2.10.2-V2.10.4p2
NUMBER:	363
MODULE:	dispcor
SYSTEM:	V2.10.2-V2.10.4p2
DATE:	Tue Mar  4 09:17:37 MST 1997
FROM:	valdes

BUG:	Input spectra which are in two dimensional images, have an 'equispec'
	coordinate system, and log sampled (DC-FLAG=1), are not properly
	resampled by DISPCOR.  One dimensional images and 'multispec'
	coordinate systems do not have this problem.  The workaround is to
	convert all the spectra to one dimensional images with SCOPY and
	format='onedspec'.

STATUS:	Fixed for the next release.