MODULE: sfit, continuum
SYSTEM: V2.10-V2.10.2
NUMBER:	320
MODULE:	sfit, continuum
SYSTEM:	V2.10-V2.10.2
DATE:	Wed Nov  8 13:54:36 MST 1995
FROM:	valdes

BUG:	If one has a list of images containing multiple spectra per image,
	such as with echelle or multifiber data,
	and one uses the SKIP option for a particular aperture followed
	by selection of skip the spectrum, then instead of just skipping the
	same aperture in all the images it will skip all the spectra in
	all the images.  The report will be a warning that there are no
	spectra to fit in the subsequent images.

	A related bug is that one may not specify a single aperture
	in the list of apertures.

STATUS:	Fixed in V2.10.3 and later.  These bugs were caused by an error in
	the ranges package.