Buglog #290
- Saturday, May 13 1995 @ 07:54 PM GMT
- Contributed by: admin
- Views: 1,023
MODULE: scopy, sarith
SYSTEM: V2.10.3
SYSTEM: V2.10.3
NUMBER: 290 MODULE: scopy, sarith SYSTEM: V2.10.3 DATE: Sat May 13 13:54:11 MST 1995 FROM: valdes BUG: When spectra are modified with SPLOT and then written out, the current display units are also recorded. SCOPY and SARITH incorrectly create new spectra with the dispersion units set to the display units. For units which are linearly related (such as any between wavelength units or between energy/frequency units) this causes no problem. However, for other pairs of units, such as dispersion units of angstroms but display units of EV, the new coordinate system will not match the spectrum pixels. The workarounds are to avoid this situation or change the 'units' in the copied/output spectrum back to the original units with WCSEDIT. STATUS: Fixed in V2.10.4