Welcome to iraf.net Friday, April 26 2024 @ 01:24 AM GMT
Buglog #255
- Tuesday, August 09 1994 @ 04:47 PM GMT
- Contributed by: admin
- Views: 1,009
MODULE: apall, apsum
SYSTEM: V2.10-V2.10.2
SYSTEM: V2.10-V2.10.2
NUMBER: 255 MODULE: apall, apsum SYSTEM: V2.10-V2.10.2 DATE: Tue Aug 9 10:47:21 MST 1994 FROM: valdes BUG: When extracting spectra with dispaxis=1 (spectra horizontal) using variance weighting and/or cleaning with a gain other than 1 then occasionally a 'floating operand error' or some arithmetic exception can occur. This is caused by reference to unitialized memory during application of the gain. The uninitialized memory does not affect the results but if an invalid arithmetic value is encountered it will cause the extraction to abort. The workarounds in this case are to use a gain of 1 if it is reasonable otherwise to transpose the image and reset the wcs (with wcsrestwcs=physical) and the dispaxis value. STATUS: Fixed after V2.10.2.