Welcome to iraf.net Thursday, March 28 2024 @ 01:23 PM GMT
Buglog #194
- Thursday, December 31 1992 @ 05:34 PM GMT
- Contributed by: admin
- Views: 1,102
MODULE: splot
SYSTEM: V2.10.2
SYSTEM: V2.10.2
NUMBER: 194 MODULE: splot SYSTEM: V2.10.2 DATE: Thu Dec 31 10:34:52 MST 1992 FROM: valdes BUG: The 'e' key in SPLOT either produces a floating operand error or a nonsensical equivalent width when the data values are less than about 1e-10 such as is the case with flux calibrated spectra. This problem was introduced due to a change in a system routine. The workaround is to scale the data, say with IMARITH or SARITH, to yield pixel values near unity. The equivalent width and wavelengths will be independent of the scaling and the other flux quantities will simply have the same scale factor. STATUS: Fixed for the next release.
The following comments are owned by whomever posted them. This site is not responsible for what they say.